Programming Description (Continued)
R6 REGISTER
The R6 register address bits (R6 [5:0]) are “011111”.
Register R6 is used for internal testing of the device and is not intended for customer use. This register is only active if the
SPI_DEF bit in register R0 is 0.
R6 REGISTER
Register
MSB
SHIFT REGISTER BIT LOCATION
LSB
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9876543210
Data Field
Address Field
R6
1
000000000000
0
0000
011111
LMX2522/LMX2532
www.national.com
17